- Published: June 1995
- Reapproved: 2019
Overview:
This International Standard specifies a method for the detection of hydrogen sulfide in
liquefied petroleum gases.
The lower limit of detectability is 4 mg of hydrogen sulfide in 1 m3 of liquefied
petroleum gas. Methyl mercaptan, if present, produces a transitory yellow stain on lead
acetate paper which, however, fades completely in less than 5 min. Other sulfur com
pounds present in liquefied petroleum gas do not in terfere with the test.
NOTE 1 Liquefied petroleum gases and the products of their combustion should not be
unduly corrosive or reactive to materials with which they come into contact. It is there fore
important that the presence of any hydrogen sulfide, a highly reactive substance, be
detected. Additionally, the odour of hydrogen sulfide is unacceptable in some applica
tions of liquefied petroleum gases (e.g. lighter fuel).
Our publications website is designed exclusively for EI members and customers to easily access and download PDF versions of our publications. For hard copies, please contact the EI Publishing Team at pubs@energyinst.org. To access previously downloaded copies go to My publications.
-
User Type
-
PDF Document
-
Hard copy
-
25% discount on most EI publications
-
Free access to other EI publications
- Technical partners
- Free
- Contact us
- Technical company members
- Free
- Contact us
- Limited access
- EI member
- £43.00
- Contact us
- Non-member
- £86.00
- Contact us
Your membership
Technical partners
-
PDF Document
Free -
Hard copy
Contact us -
Free access to other EI publications
Your membership
Technical company members
-
PDF Document
Free -
Hard copy
Contact us -
Limited access to other EI publications
Your membership
EI member
-
PDF Document
£43.00 -
Hard copy
Contact us -
Limited access to other EI publications
Your membership
Non-member
-
PDF Document
£86.00 -
Hard copy
Contact us -
Limited access to other EI publications